Main Page → Motive Documentation → Synchronization → Properties: OptiHub
By modifying the device properties of the OptiHub, users can customize the sync configurations of the camera system for implementing external devices in various sync chain setups. This page directly lists out the properties of the OptiHub. For general instructions on customizing sync settings for integrating external devices, it is recommended to read through the External Device Sync: OptiHub guide.
While the OptiHub is selected under the Devices pane, use the Properties pane to view and configure its properties. By doing so, users can set the master sync source for the camera system, configure how the system reacts to input signals, and also which signals to output from the OptiHub for triggering other external acquisition devices.
To setup the sync input signals, first define a input Source and configure desired trigger settings for the source:
The Internal/Wired input source uses the OptiHub's internal synchronization generator as the main sync source. You can modify the synchronization frequency for both Wired and OptiSync protocol under the Synchronization Control section. When you adjust the system frame rate from this panel, the modified frame rate may not be reflected on the Devices pane. Check the streaming section of the status bar for the exact information.
This option is only valid if the Sync Input: Source is set to Internal Sync. Controls the frequency in Hertz (Hz) of the OptiHub's internal sync generator, and the this frequency will control the camera system frame rate. Valid frequency range is 8 to 120 Hz.
The Sync In input source setting uses signals coming into the input ports of the OptiHub to trigger the synchronization. Please refer to External Device Sync Guide: OptiHub page for more instructions on this.
Detects and displays the frequency of the sync signal that's coming through the input port of the master OptiHub, which is at the very top of the RCA sync chain. When sync source is set to Sync In, the camera system framerate will be synchronized to this input signal. Please note that OptiHub is not designed for precise sync, so there may be slight sync discrepancies when synchronizing through OptiHub.
Manually adds global sync time offset to how camera system reacts to the received input signal. The input unit is measured in microseconds.
Can select from Either Edge, Rising Edge, Falling Edge, Low Gated, or High Gated signal from the connected input source.
Allows a triggering rate compatible with the camera frame rate to be derived from higher frequency input signals (e.g. 300Hz decimated down to 100Hz for use with a V100:R2 camera). Valid range is 1 (no decimation) to 15 (every 15th trigger signal generates a frame).}}
(The camera system will be the slave) sets an external USB device as the sync source. This mode is for customers who use the Camera SDK development kits and would like to have their software trigger the cameras instead. Using the providede API, the OptiHub will be send the trigger signal from the PC via the OptiHib's USB uplink connection to the PC.
Detects and displays the freqyency of the master source.
Allows the user to allow or block trigger events generated by the internal sync control. This option has been deprecated for use in the GUI. Valid options are Gate-Open and Gate-Closed.
Allows a triggering rate compatible with the camera frame rate to be derived from higher frequency input signals (e.g. 360Hz decimated down to 120Hz for use with a Flex 13 camera). Valid range is 1 (no decimation) to 15 (every 15th trigger signal generates a frame).}}
Sync signals can also be sent out through the output ports of the OptiHub to slave devices in the synchronization chain. Read more: External Device Sync Guide: OptiHub.
Selects condition and timing for a pulse to be sent out over the External Sync Out jack. Available Types are: Exposure Time, Pass-Through, Recording Level, and Recording Pulse.